Glaunach · Vent Silencers
GLAUNACH hydrogen vent accessories: lambda vent, rain cap, deflector
Lambda vent for upward discharge and dilution to DVGW G 442, H₂ rain cap with rain-resistant vent, vertical discharge deflector and drainage for hydrogen silencers.
Four additions make a hydrogen vent safe as well as quiet. The lambda vent turns the discharge upward so the hydrogen dilutes quickly and the hazardous zone stays within DVGW G 442. The rain cap keeps rain and snow out while still letting hydrogen escape after operation, so it cannot accumulate in the silencer. The vertical discharge deflector converts a horizontal outlet into an upward one, and the drainage removes condensate before it can reach the vent line.
Selection data we need
Silencer type and outlet size, hazardous-area classification, discharge direction, installation site.
Applications
- Outlets of inline hydrogen silencers
- Hydrogen vents in classified areas
- Horizontal vents that must discharge vertically